Windsor Range of Stainless Steel Wire Balustrades with Stainless Steel Posts
IF YOU HAVE ANY QUESTIONS ON YOUR WIRE BALUSTRADING, PLEASE CONTACT US ON 01628 526995.
Stainless Steel Posts and fittings are available for Decking in either grade 304 (standard) or marine grade (316). Marine grade should be used within 5 miles of the sea or around swimming pools. Stainless Steel Wire is always marine grade 316.
A single run of up to 25 metres of Stainless Steel Wire may be used when the run is a straight line. A single run may also be used when there are no more than 2 changes of angle, but in this case the maximum run is 15 metres.
The wire can pass through intermediate newel posts, and is joined to the end newel posts by an End Fixing Unit.
Please phone us if the wire length required exceeds any of the maximum lengths .
Normally we recommend 4 wires per balustrade, but note that a wire balustrade will not satisfy Building Regulations as children can climb them.

This Stainless Steel Wire Balustrade with WINDSOR Stainless Steel Posts is only available on level Decking.
In order to make the correct lengths of wire, we will need your requirements for each section.
Please email janmoorhouse@btconnect.com together with a rough sketch of the balustrading.
We will assume that wires are spread evenly over the post, unless you tell us to the contrary.
Stainless Steel Posts and Handrail Units for WINDSOR Balustrade (Unit Price inc. VAT) |
||||||
|
|
|||||
|
|
|||||
|
|
|||||
|
|
|||||
|
|
|||||
|
|
|||||
|
|
|||||
Stainless Steel Marine Grade Wire and Fixings for WINDSOR balustrade |
|||||
|
|
||||
|
|
||||
Windsor Stainless Steel Wire with Stainless Steel Posts Assembly Instructions
These assembly instructions only relate to horizontal stainless steel balustrading. We are unable to supply stainless steel balustrading for steps.
1. Erect Stainless Steel Upright Posts.
2. Put Steel Cover Plate over base plate.
3. Attach Saddles/Universal Fittings to pre-drilled rails with self tapping screws (supplied).
4. Assemble and glue rail plus saddles and/or elbows into top of Upright Posts.
5. If the posts have the wire already threaded through the posts, then attach the End Fixing Units to each end newel post and tighten the wires.
6. If the posts do not have the wire already threaded through the posts, then
a) Attach the End Fixing Unit to one external pre drilled end post.
b) Thread the wire through the intermediary posts.
c) Attach the Swageless Unit to the other end (instructions supplied) and cut off the surplus wire.